Abstract
To compare the marginal leakage of CAD/CAM-fabricated ceramic inlay, gold inlay and amalgam, forty extracted caries-free premolars were prepared with Class MO cavity design. The teeth were divided into four groups of ten samples each. Group 1 was restored with CAD/CAM-fabricated ceramic inlays cemented with Scotchbond Resin Cement / Scotchbond Multi-purpose plus. Group 2 was restored with gold inlays cemented with Scotchbond Resin Cement / Scotchbond Multi-purpose plus. Group 3 was restored with gold inlays cemented with zinc phosphate cement. And, Group 4 was restored with amalgam. All samples were thermocycled, and stored in 1% methylene blue. Marginal leakage was examined at four margins, that is, occlusal distal, priximal gingival, occlsal facial and occlusal lingual margins from sectioned samples under steeomicroscope(x15).
The results were as follows:
1. Group 1 and 2 showed no statistically significant difference among marginal leakage at all four examined margins(p0.05).
2. Group 3 and 4 showed significant marginal leakage at proximal gingival margin compared with other margins(p0.05).
3. Significantly increased marginal leakage at priximal gingival, occlusal facial and occlusal lingual margins in group 3 were observed compared with other groups(p0.05).
ISSN
1225-0864
Language
Korean
URI
https://hdl.handle.net/10371/47883
Files in This Item:
Appears in Collections:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share