In-situ measurements of indoor dust deposition in Sistan region, Iran-the effect of windcatcher orientation

  1. 1.
    0557523 - ÚT 2023 RIV NL eng J - Článek v odborném periodiku
    Miri, A. - Heidari, A. - Davtalab, J. - Nosek, Štěpán - Abdolzadeh, M.
    In-situ measurements of indoor dust deposition in Sistan region, Iran-the effect of windcatcher orientation.
    Building and Environment. Roč. 219, July (2022), č. článku 109162. ISSN 0360-1323. E-ISSN 1873-684X
    Institucionální podpora: RVO:61388998
    Klíčová slova: windcatcher * climatic * kolak * Dust * air velocity * sistan
    Obor OECD: Meteorology and atmospheric sciences
    Impakt faktor: 7.4, rok: 2022
    Způsob publikování: Omezený přístup
    https://www.sciencedirect.com/science/article/pii/S0360132322003997

    Windcatcher is a climatic design element of buildings used for cooling in Sistan of Iran. Siatan has become a dust hotspot, and thus windcatcher should be designed with respect to dust storms for utilizing wind for cooling, on the one hand, and deal with harsh conditions (such as dust particles) on the other hand. In this paper, two identical spaces, consisting of two interconnected rooms (collectively four rooms namely R1, R2, R3, and R4), were examined to assess the dust movement and deposition in the buildings. Rooms R1 and R2 had two windcatchers facing the prevailing wind of the region, and R3 and R4 had windcatchers in the opposite direction of the prevailing wind. Air velocities in the rooms were measured in the centre and adjacent to the left and right sidewalls at heights of 10, 50, 80, 150, 180, and 200 cm. The dust deposition density was measured using 288 samplers which were placed on floors of the rooms. Most dust particles were silt, and the patterns of particle size distribution were similar in the two interconnected rooms (Rooms R1&R2 and rooms R3&R4). Results showed that the airflow enters and leaves rooms R1 & R2 and rooms R3 & R4, respectively. Rooms R2 and R4 had the highest (206.08 g m-2) and the lowest (14.98 g m-2) dust deposition density, respectively. Different spatial patterns of the dust deposition were observed between the studied rooms and were consistent with the orientation of the Kolaks.
    Trvalý link: https://hdl.handle.net/11104/0332773

     
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.