Počet záznamů: 1  

Hydrophilic Interaction Liquid Chromatography–Hydrogen/Deuterium Exchange–Mass Spectrometry (HILIC-HDX-MS) for Untargeted Metabolomics

  1. 1.
    0583841 - FGÚ 2025 RIV CH eng J - Článek v odborném periodiku
    Čajka, Tomáš - Hricko, Jiří - Rakušanová, Stanislava - Brejchová, Kristýna - Nováková, Michaela - Rudl Kulhavá, Lucie - Holá, Veronika - Paučová, Michaela - Fiehn, O. - Kuda, Ondřej
    Hydrophilic Interaction Liquid Chromatography–Hydrogen/Deuterium Exchange–Mass Spectrometry (HILIC-HDX-MS) for Untargeted Metabolomics.
    International Journal of Molecular Sciences. Roč. 25, č. 5 (2024), č. článku 2899. ISSN 1661-6596
    Grant CEP: GA MŠMT(CZ) LX22NPO5104; GA ČR(CZ) GA20-21114S; GA ČR(CZ) GA21-00477S
    Výzkumná infrastruktura: e-INFRA CZ II - 90254
    Institucionální podpora: RVO:67985823
    Klíčová slova: metabolomics * liquid chromatography * mass spectrometry * hydrogen/deuterium exchange * unknown identification
    Obor OECD: Analytical chemistry
    Impakt faktor: 5.6, rok: 2022
    Způsob publikování: Open access
    https://www.mdpi.com/1422-0067/25/5/2899

    Liquid chromatography with mass spectrometry (LC-MS)-based metabolomics detects thousands of molecular features (retention time–m/z pairs) in biological samples per analysis, yet the metabolite annotation rate remains low, with 90% of signals classified as unknowns. To enhance the metabolite annotation rates, researchers employ tandem mass spectral libraries and challenging in silico fragmentation software. Hydrogen/deuterium exchange mass spectrometry (HDX-MS) may offer an additional layer of structural information in untargeted metabolomics, especially for identifying specific unidentified metabolites that are revealed to be statistically significant. Here, we investigate the potential of hydrophilic interaction liquid chromatography (HILIC)-HDX-MS in untargeted metabolomics. Specifically, we evaluate the effectiveness of two approaches using hypothetical targets: the post-column addition of deuterium oxide (D2O) and the on-column HILIC-HDX-MS method. To illustrate the practical application of HILIC-HDX-MS, we apply this methodology using the in silico fragmentation software MS-FINDER to an unknown compound detected in various biological samples, including plasma, serum, tissues, and feces during HILIC-MS profiling, subsequently identified as N1-acetylspermidine.
    Trvalý link: https://hdl.handle.net/11104/0351844

     
    Název souboruStaženoVelikostKomentářVerzePřístup
    24_0026_0583841.pdf4849.4 KBVydavatelský postprintpovolen
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.