An investigation on compatibility properties of exterior finish coats for insulated walls in terms of water vapour pemeability and modulus ofelasticity

Download
2006
Örs, Kerime
The compatibility properties of some contemporary finish coats together with their complementary layers used in insulated exterior walls were examined in terms of water vapour permeability and modulus of elasticity. Basic physical and mechanical properties of some synthetic-, cement- and polymer-based external finish coats were analyzed in laboratory. Some additional samples, complementing the wall section, were also examined for their water vapour permeability. Results showed that the finish coats were high vapour permeable although they had high resistance to water vapour permeation, which was achieved by their application in thin layers. Cement-based undercoats were found to be medium permeable. The application of primer and/or paint was found to decrease the permeability of finish coats in different ranges. Thermal insulation layer was found to interrupt water vapour flow considerably. Among polystyrene- and mineral-wool-based thermal insulation boards, rockwool was recommended as the insulation layer due to its medium vapour permeability. In conclusion, walls insulated externally with rockwool boards and plastered with polymer-based finish coat, FC8ACB or synthetic-based finish coat FC3SB were found to be the most proper combination in terms of breathing and thermal resistance capabilities. All finish coats seemed to have sufficient strength and except the synthetic-based finish coat, FC2SB, they seemed to be compatible with each other and with the masonry in terms of their Emod values. Further studies were recommended on some other compatibility properties of finishing systems, such as thermal and moisture dilatation properties, and on the relation between the resistance to water vapour permeation and water permeability.

Suggestions

Analytical prediction of thermal displacement capacity of integral bridges built on sand
Dicleli, Murat (SAGE Publications, 2005-02-01)
In this research, analytical equations are developed to calculate the lateral displacement capacity and maximum length limits of integral bridges built on sand based on the low-cycle fatigue performance of the piles under cyclic thermal variations and the ultimate strength of the abutment under positive thermal variations. To formulate the displacement capacity and maximum length limits of integral bridges based on the low cycle fatigue performance of steel H-piles under cyclic thermal variations, first, H-...
A study on material properties of autoclaved aerated concrete (AAC) and its complementary wall elements : their compatibility in comtemporary and historical wall sections
Andolsun, Simge; Tavukçuoğlu, Ayşe; Department of Building Science in Architecture (2006)
Examined in this study were some physical, mechanical, compositional and durability properties of AAC, its neighboring plasters and jointing adhesive, all of which were produced in Turkey. The compatibility of these materials inside the contemporary wall section and within historic fabric was discussed in terms of their material properties. In addition to the literature survey, laboratory studies were conducted on two types of AAC as G2 and G4, its jointing adhesive and exterior finishing layers as base coa...
Determination of a price index for escalation of building construction costs in Turkey
Kahraman, Serhan; Sönmez, Rifat; Department of Civil Engineering (2005)
Construction cost indices are developed to measure the degree of price variations in construction material and labor costs. However, each specific type of construction is a combination of unique set of materials and labor. As such, the degree of price variations referring to each specific type of construction shall be measured by specific price indices, in order to achieve more accurate results. In Turkey, Producer Price Index (PPI) published by State Statistics Institute is commonly used for the escalation...
A numerical study on local buckling and energy dissipation of CHS seismic bracing
Kusyilmaz, Ahmet; Topkaya, Cem (Elsevier BV, 2011-08-01)
Seismic provisions for steel buildings present limiting width-thickness and slenderness ratios for bracing members, most of which were established based on experimental observations. A finite element study has been undertaken to evaluate these limits for pin-ended circular hollow section (CHS) steel braces. Uncertainties in modeling and quantification arise in the simulation of cyclic brace buckling. A finite element modeling procedure was developed and calibrated using existing experimental data. Sensitivi...
Analytical Investigation of Lateral Strength of Masonry Infilled RC Frames Retrofitted with CFRP
Erdem, Ibrahim; Akyüz, Uğurhan (American Society of Civil Engineers (ASCE), 2010-07-01)
In this study, two reinforced concrete frames with hollow clay tile masonry infill walls, retrofitted with diagonally applied carbon fiber-reinforced polymer (CFRP), which were tested previously, were analytically investigated. A simple material model for the masonry infill wall strengthened with CFRP is suggested. The lateral strength of each rehabilitated frame was obtained by pushover analysis of four different models using a commercially available finite-element program, and the results were compared wi...
Citation Formats
K. Örs, “An investigation on compatibility properties of exterior finish coats for insulated walls in terms of water vapour pemeability and modulus ofelasticity,” M.S. - Master of Science, Middle East Technical University, 2006.