English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

Hypercapnia-induced effects on image contrast based on intermolecular double-quantum coherences

MPS-Authors
/persons/resource/persons19963

Schäfer,  Andreas
Department Neurophysics, MPI for Human Cognitive and Brain Sciences, Max Planck Society;

/persons/resource/persons20125

Zysset,  Stefan
Department Cognitive Neurology, MPI for Human Cognitive and Brain Sciences, Max Planck Society;

/persons/resource/persons19864

Möller,  Harald E.
Methods and Development Unit Nuclear Magnetic Resonance, MPI for Human Cognitive and Brain Sciences, Max Planck Society;

External Resource
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)
There is no public supplementary material available
Citation

Schäfer, A., Zysset, S., Heinke, W., & Möller, H. E. (2008). Hypercapnia-induced effects on image contrast based on intermolecular double-quantum coherences. Magnetic Resonance in Medicine, 60(6), 1306-1312. doi:10.1002/mrm.21768.


Cite as: https://hdl.handle.net/11858/00-001M-0000-0010-BAD1-4
Abstract
Intermolecular double-quantum coherences (iDQCs) are well known to be sensitive to magnetic-field perturbations inside tissues. However, the exact relation between iDQC contrast in magnetic resonance imaging (MRI) and the underlying physiology is less well understood. To investigate parameters that influence iDQC signal changes observed during neuronal activation, carbogen-inhalation experiments were performed to produce a pure hemodynamic response without affecting oxidative metabolism. Eight human volunteers were studied at 2.9 T using gradient-recalled echo (GRE) and spin-echo (SE) variants of a single-shot sequence selecting iDQCs. Results were compared with conventional recordings of the blood oxygen level-dependent (BOLD) effect. Maps of voxels responding to the carbogen challenge showed similar distributions for iDQC and conventional MRI after adjustment for different sensitivities. Strong diffusion weighting of iDQC sequences and transverse relaxation effects suggested quantitative suppression of intravascular signal contributions. A particular susceptibility to local gradients during the evolution period (in which iDQCs evolve at twice the Larmor frequency) plus a strong relaxation weighting during the detection period due to the use of a long echo time (for refocusing of the dipolar signal) produced iDQC signal changes up to 21.7% ± 2.5%. These results agreed quantitatively with computations based on the balloon model of BOLD-weighted MRI without requiring further assumptions. © 2008 Wiley-Liss, Inc.