Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT

Freigegeben

Zeitschriftenartikel

Optical resonator with steep internal dispersion

MPG-Autoren

Müller,  G.
Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;
AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;

Müller,  M.
Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;
AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;

Wicht,  A.
Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;
AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;

Rinkleff,  Rolf-Hermann
Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;
AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;

/persons/resource/persons40437

Danzmann,  Karsten
Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;

Externe Ressourcen
Es sind keine externen Ressourcen hinterlegt
Volltexte (beschränkter Zugriff)
Für Ihren IP-Bereich sind aktuell keine Volltexte freigegeben.
Volltexte (frei zugänglich)

372225.pdf
(Verlagsversion), 115KB

Ergänzendes Material (frei zugänglich)
Es sind keine frei zugänglichen Ergänzenden Materialien verfügbar
Zitation

Müller, G., Müller, M., Wicht, A., Rinkleff, R.-H., & Danzmann, K. (1997). Optical resonator with steep internal dispersion. Physical Review A, 56(3), 2385-2389. doi:10.1103/PhysRevA.56.2385.


Zitierlink: https://hdl.handle.net/11858/00-001M-0000-0013-5A88-A
Zusammenfassung
We present an optical resonator with modified properties due to a nonabsorbing highly dispersive medium. The steep nonabsorbing dispersion is created with an additional pump field in an atomic beam using the effect of coherent population trapping. The linewidth of such a resonator depends on the slope of the dispersion line, which in turn depends on the atomic density and the intensity of pump and probe field. In the experiments presented here, the cavity linewidth is reduced by a factor of more than 50 relative to the linewidth of the empty resonator. We have studied the influence of the relative intensities of pump and probe field on the line profile. Due to the dispersion of the medium, the resonance frequency is nearly independent of the geometrical length of the resonator.