THE USE OF SURFACE HOT-FILM SENSORS IN DILUTE POLYMER FLOWS

Date
1987
Journal Title
Journal ISSN
Volume Title
Publisher
Description
Abstract

The purpose of this study was to assess the feasibility of using flush-mounted surface hot-film sensors in dilute polymer solutions to measure mean wall shear stress. Experiments were conducted using hot-film sensors mounted on the surface of a rotating disk. It is shown that a sensor calibration obtained in a pure water flow cannot be used directly to provide accurate skin friction measurements in a dilute polymer flow. However, the repeatability of the results suggests that a functional relation may exist between a sensor's calibration in water and in dilute polymer, thereby permitting precalibration of the sensor in pure water. It is also possible that reasonably consistent measurements may be obtained by precalibration of sensors in controlled polymer solutions. Experiments were also conducted by injecting concentrated polymer solution (4000 ppm) into the boundary layer of the rotating disk. Drag reduction and hot-film performance comparable to that obtained with homogeneous dilute polymer solution was demonstrated.

Description
Advisor
Degree
Master of Science
Type
Thesis
Keywords
Mechanical engineering
Citation

GOFORTH, MONTGOMERY BAILEY. "THE USE OF SURFACE HOT-FILM SENSORS IN DILUTE POLYMER FLOWS." (1987) Master’s Thesis, Rice University. https://hdl.handle.net/1911/13220.

Has part(s)
Forms part of
Published Version
Rights
Copyright is held by the author, unless otherwise indicated. Permission to reuse, publish, or reproduce the work beyond the bounds of fair use or other exemptions to copyright law must be obtained from the copyright holder.
Link to license
Citable link to this page