Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT

Freigegeben

Meeting Abstract

Human in-vivo Magnetic Resonance Current Density Imaging (MRCDI) and MR Electrical Impedance Tomography (MREIT)

MPG-Autoren
/persons/resource/persons83898

Ehses,  P
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84187

Scheffler,  K
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

Volltexte (beschränkter Zugriff)
Für Ihren IP-Bereich sind aktuell keine Volltexte freigegeben.
Volltexte (frei zugänglich)
Es sind keine frei zugänglichen Volltexte in PuRe verfügbar
Ergänzendes Material (frei zugänglich)
Es sind keine frei zugänglichen Ergänzenden Materialien verfügbar
Zitation

Göksu, C., Hanson, L., Siebner, H., Ehses, P., Scheffler, K., & Thielscher, A. (2018). Human in-vivo Magnetic Resonance Current Density Imaging (MRCDI) and MR Electrical Impedance Tomography (MREIT). Physica Medica, 52(Supplement 1): OA019, 8.


Zitierlink: https://hdl.handle.net/21.11116/0000-0001-F71E-8
Zusammenfassung
Purpose Information on the electrical tissue conductivity might be useful for the diagnosis and characterization of pathologies such as tumors [1]. MRCDI and MREIT are two emerging non-invasive techniques for imaging of weak currents and ohmic conductivities. In this study, we demonstrated human in vivo brain MRCDI to pave the way for its clinical use [2], [3]. Methods In short, weak alternating currents up to 1–2 mA are injected into human head in synchrony with tailored phase-sensitive MRI. The currents create a magnetic field , which shifts the precession frequency of the magnetization and modulates the acquired MR images. The acquired images are used to measure and reconstruct the current flow and conductivity distributions. We employed a steady-state free precession free-induction-decay (SSFP-FID) sequence in five subjects, and injected currents of 1 mA by an MR-conditional current source via electrodes attached to the scalp (two current profiles: Right-left (RL), electrodes placed near the temporoparietal junctions; anterior-posterior (AP), one attached to the forehead and one above the inion). Additionally, an ultra-short-echo-time sequence was performed to track the feeding cables for correcting the stray magnetic fields induced by cable currents. Corrected measurements were used to calculate current flow distributions and compared with Finite-Element simulations of the current flow based on individualized head models [4]. Results The current-induced magnetic field with was reliably measured and the reconstructed current flows showed good agreement with the simulations (average coefficient of determination R2= 71%). The injected current flow differed substantially among individuals according to the electrode placements and anatomical differences. The calculated currents are stronger in CSF-filled highly conductive regions, e.g. the longitudinal fissure. Conclusions The strong correlation between the simulations and measurements validates the accuracy of the method and demonstrates the potential of the method for determining accurate brain tissue conductivities. These initial current flow recordings pave the way for human brain MREIT that might complement standard MR methods for tumor characterization.