Performance Measurements on the MPI Stewart Platform

MPG-Autoren
/persons/resource/persons84111

Nieuwenhuizen,  FM
Department Human Perception, Cognition and Action, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons83808

Beykirch,  K
Department Human Perception, Cognition and Action, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons83821

Bonten,  JLG
Department Human Perception, Cognition and Action, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons83839

Bülthoff,  HH
Department Human Perception, Cognition and Action, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

Externe Ressourcen
Volltexte (beschränkter Zugriff)
Für Ihren IP-Bereich sind aktuell keine Volltexte freigegeben.
Volltexte (frei zugänglich)
Es sind keine frei zugänglichen Volltexte in PuRe verfügbar
Ergänzendes Material (frei zugänglich)
Es sind keine frei zugänglichen Ergänzenden Materialien verfügbar
Zitation

Nieuwenhuizen, F., Beykirch, K., Mulder, M., van Paassen, M., Bonten, J., & Bülthoff, H. (2008). Performance Measurements on the MPI Stewart Platform. In AIAA Modeling and Simulation Technologies Conference 2008 (pp. 401-411). Red Hook, NY, USA: Curran.


Zitierlink: https://hdl.handle.net/11858/00-001M-0000-0013-C7CB-5
Zusammenfassung
The report AGARD-AR-144 provides a framework for systematically assessing the dynamic characteristics of flight simulator motion systems. Several measurements defined in the report were performed on the Stewart platform located at the Max Planck Institute for Biological Cybernetics. The measurements were performed with a setup consisting of real-time hardware and an off-the-shelf IMU. Results indicated that the motion platform describing functions were very similar to the standard motion filters implemented by the platform manufacturer, but included a time delay of 100 ms. The total noise of the system mainly consisted of stochastic and high-frequency non-linear components, that were attributed to the IMU. The measurements defined by AGARD-144 proved to provide useful insight into the platform characteristics.