Article (Scientific journals)
Diagnostic accuracy of computed tomography coronary angiography in routine practice
Davin, Laurent; LANCELLOTTI, Patrizio; BRUYERE, Pierre-Julien et al.
2007In Acta Cardiologica, 62 (4), p. 339-344
Peer Reviewed verified by ORBi
 

Files


Full Text
DAVIN_ActaCardiol_2007_62_339.pdf
Publisher postprint (876.46 kB)
Request a copy

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
coronary angiography; MSCT; coronary artery disease
Abstract :
[en] Objectives - The recent newer advances in computed tomography have dramatically changed our approach to imaging cardiac disease. This study sought to compare the diagnostic value of 16-multi-detector spiral computed tomography (MSCT) for detecting coronary artery stenosis. Methods - A total of 88 consecutive patients (52 men, mean age 68 +/- 8 years) with atypical chest pain, stable angina or suspicion of ischaemia at stress test were studied by MSCT and invasive coronary angiography (ICA). The MSCT images and multiplanar reconstructions were analysed regarding the presence of >= 50% coronary artery lesion. Results - All 88 scans obtained at a mean heart rate of 68 8 beats/min were interpretable. Sixteen coronary segments were evaluated in each patient. Of the 1320 segments examined, 148 (11 %) showed poor image quality. A total of 150 significant lesions were detected using ICA, and 80 of 150 (53%) were detected by MSCT Sensitivity, specificity, positive and negative predictive values were as follows: 53%, 97%, 68%, and 94%. Fifty-four patients had >= 50% coronary stenosis. The diagnosis was confirmed by MSCT in 42 patients and correctly ruled out in 30. By patient-based analysis, positive and negative predictive values were 91 % and 71 %. Conclusion - Although its specificity is high, the sensitivity of 16-slice MSCT for detecting 2: 50% coronary stenosis in non-selected patients submitted to ICA is rather low suggesting that for daily practice the diagnostic value of this technique should be improved.
Disciplines :
Cardiovascular & respiratory systems
Author, co-author :
Davin, Laurent ;  Centre Hospitalier Universitaire de Liège - CHU > Cardiologie
LANCELLOTTI, Patrizio  ;  Centre Hospitalier Universitaire de Liège - CHU > Cardiologie
BRUYERE, Pierre-Julien ;  Centre Hospitalier Universitaire de Liège - CHU > Département de Physique Médicale > Service médical de radiodiagnostic
Gach, Olivier ;  Centre Hospitalier Universitaire de Liège - CHU > Cardiologie
Pierard, Luc ;  Université de Liège - ULiège > Département des sciences cliniques > Cardiologie - Pathologie spéciale et réhabilitation
Legrand, Victor ;  Université de Liège - ULiège > Département des sciences cliniques > Cardiologie
Language :
English
Title :
Diagnostic accuracy of computed tomography coronary angiography in routine practice
Publication date :
August 2007
Journal title :
Acta Cardiologica
ISSN :
0001-5385
eISSN :
1784-973X
Publisher :
Acta Cardiologica, Brussels, Belgium
Volume :
62
Issue :
4
Pages :
339-344
Peer reviewed :