Article (Scientific journals)
High-throughput biomonitoring of dioxins and polychlorinated biphenyls at the sub-picogram level in human serum
Focant, Jean-François; Eppe, Gauthier; Massart, Anne-Cécile et al.
2006In Journal of Chromatography. A, 1130 (1), p. 97-107
Peer Reviewed verified by ORBi
 

Files


Full Text
Focant et al.pdf
Publisher postprint (569.85 kB)
Request a copy

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
solid-phase extraction; isotope dilution; high-resolution mass spectrometry; human serum; biomonitoring; polychlorinated dibenzo-p-dioxins; polychlorinated dibenzofurans; polychlorinated biphenyls; limit of quantification; multi-level quality control
Abstract :
[en] We report on the use of a state-of-the-art method for the measurement of selected polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans and polychlorinated biphenyls in human serum specimens. The sample preparation procedure is based on manual small size solid-phase extraction (SPE) followed by automated clean-up and fractionation using multi-sorbent liquid chromatography columns. SPE cartridges and all clean-up columns are disposable. Samples are processed in batches of 20 units, including one blank control (BC) sample and one quality control (QC) sample. The analytical measurement is performed using gas chromatography coupled to isotope dilution high-resolution mass spectrometry. The sample throughput corresponds to one series of 20 samples per day, from sample reception to data quality cross-check and reporting, once the procedure has been started and series of samples keep being produced. Four analysts are required to ensure proper performances of the procedure. The entire procedure has been validated under International Organization for Standardization (ISO) 17025 criteria and further tested over more than 1500 unknown samples during various epidemiological studies. The method is further discussed in terms of reproducibility, efficiency and long-term stability regarding the 35 target analytes. Data related to quality control and limit of quantification (LOQ) calculations are also presented and discussed. (c) 2006 Elsevier B.V. All rights reserved.
Disciplines :
Chemistry
Biochemistry, biophysics & molecular biology
Author, co-author :
Focant, Jean-François  ;  Université de Liège - ULiège > Département de chimie (sciences) > Chimie analytique
Eppe, Gauthier  ;  Université de Liège - ULiège > Centre interfac. d'analyse des résidus en traces (CART)
Massart, Anne-Cécile ;  Université de Liège - ULiège > Centre interfac. d'analyse des résidus en traces (CART)
Scholl, Georges ;  Université de Liège - ULiège > Centre interfac. d'analyse des résidus en traces (CART)
PIRARD, Catherine  
De Pauw, Edwin  ;  Université de Liège - ULiège > Chimie physique, spectrométrie de masse
Language :
English
Title :
High-throughput biomonitoring of dioxins and polychlorinated biphenyls at the sub-picogram level in human serum
Publication date :
13 October 2006
Journal title :
Journal of Chromatography. A
ISSN :
0021-9673
eISSN :
1873-3778
Publisher :
Elsevier Science Bv, Amsterdam, Netherlands
Volume :
1130
Issue :
1
Pages :
97-107
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 08 July 2009

Statistics


Number of views
147 (23 by ULiège)
Number of downloads
7 (6 by ULiège)

Scopus citations®
 
27
Scopus citations®
without self-citations
12
OpenCitations
 
26

Bibliography


Similar publications



Contact ORBi