1, 25 dihydroxyvitamin D; 25 hydroxyvitamin D; Vitamin D Metabolism Ratio (VMR); standardization
Abstract :
[en] Total 25-hydroxyvitamin D is currently considered as the most representative metabolite of vitamin D status. There are a multitude of challenges that still deserve to be addressed and despite recent technological advances its determination remains complicated. This current review gives an abbreviated overview of the phases of development that vitamin D metabolite determination has gone through and discusses the difficulties that still require resolving. Furthermore, given the different platforms and methodologies available, the critical issue of standardization and all efforts made as far towards its realization have been discussed. And last but not least, the concepts of 'free' and 'bioavailable' vitamin D along with the 'Vitamin D Metabolism Ratio' have been discussed.
Disciplines :
Laboratory medicine & medical technology
Author, co-author :
Cavalier, Etienne ; Université de Liège - ULiège > Département de pharmacie > Chimie médicale
Souberbielle, Jean-Claude
Language :
English
Title :
Vitamin D and its metabolites: from now and beyond.
Publication date :
2018
Journal title :
eJIFCC: Electronic journal of the International Federation of Clinical Chemistry and Laboratory Medicine
eISSN :
1650-3414
Publisher :
International Federation of Clinical Chemistry and Laboratory Medicine (IFCC), Milano, Italy
Ross AC, Manson JE, Abrams SA, et al. (2011) The 2011 report on dietary reference intakes for calcium and Vitamin D from the Institute of Medicine: what clinicians need to know. J Clin Endocrinol Metab 96:53-58.
Holick MF, Binkley NC, Bischoff-Ferrari HA, et al. (2012) Guidelines for preventing and treating Vitamin D deficiency and insufficiency revisited. J Clin Endocrinol Metab 97:1153-1158.
Hollis BW (2004) The determination of circulating 25-hydroxyVitamin D: No easy task. J Clin Endocrinol Metab 89:3149-3151.
Moreau E, Bächer S, Mery S, et al. (2015) Performance characteristics of the VIDAS® 25-OH Vitamin D Total assay-comparison with four immunoassays and two liquid chromatography-tandem mass spectrometry methods in a multicentric study. Clin Chem Lab Med.
Depreter B, Heijboer AC, Langlois MR (2013) Accuracy of three automated 25-hydroxyVitamin D assays in hemodialysis patients. Clin Chim Acta 415:255-260.
Heijboer AC, Blankenstein M a., Kema IP, Buijs MM (2012) Accuracy of 6 routine 25-hydroxyVitamin D assays: Influence of Vitamin D binding protein concentration. Clin Chem 58:543-548.
Cavalier E, Lukas P, Crine Y, et al. (2014) Evaluation of automated immunoassays for 25(OH)-Vitamin D determination in different critical populations before and after standardization of the assays. Clin Chim Acta 431:60-65.
Carter GD, Jones JC, Berry JL (2007) The anomalous behaviour of exogenous 25-hydroxyVitamin D in competitive binding assays. J Steroid Biochem Mol Biol 103:480-482.
Horst RL (2010) Exogenous versus endogenous recovery of 25-hydroxyvitamins D2 and D3 in human samples using high-performance liquid chromatography and the DiaSorin LIAISON Total-D Assay. J Steroid Biochem Mol Biol 121:180-182.
Lankes U, Elder P a., Lewis JG, George P (2015) Differential extraction of endogenous and exogenous 25-OH-Vitamin D from serum makes the accurate quantification in liquid chromatography-tandem mass spectrometry assays challenging. Ann Clin Biochem An Int J Biochem Lab Med 52:151-160.
Hollis BW, Kamerud JQ, Selvaag SR, et al. (1993) Determination of Vitamin D status by radioimmunoassay with an 125I-labeled tracer. Clin Chem 39:529-533.
Omi K, Ando T, Sakyu T, et al. (2015) Noncompetitive Immunoassay Detection System for Haptens on the Basis of Antimetatype Antibodies. Clin Chem 61:627-635.
Wise SA, Phinney KW, Tai SSC, et al. (2017) Baseline Assessment of 25-HydroxyVitamin D Assay Performance: A Vitamin D Standardization Program (VDSP) Interlaboratory Comparison Study. J AOAC Int 100:1244-1252.
Cavalier E, Lukas P, Bekaert A-C, et al. (2016) Analytical and clinical evaluation of the new Fujirebio Lumipulse®G non-competitive assay for 25(OH)-Vitamin D and three immunoassays for 25(OH)D in healthy subjects, osteoporotic patients, third trimester pregnant women, healthy African subjects, hemodiadialyzed and intensive care patients. Clin Chem Lab Med 54(8):1347-55.
Tai SS-C, Bedner M, Phinney KW (2010) Development of a candidate reference measurement procedure for the determination of 25-hydroxyVitamin D3 and 25-hydroxyVitamin D2 in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry. Anal Chem 82:1942-1948.
Stepman HCM, Vanderroost A, Van Uytfanghe K, Thienpont LM (2011) Candidate Reference Measurement Procedures for Serum 25-HydroxyVitamin D3 and 25-HydroxyVitamin D2 by Using Isotope-Dilution Liquid Chromatography-Tandem Mass Spectrometry. Clin Chem 57:441-448.
Stöckl D, Sluss PM, Thienpont LM (2009) Specifications for trueness and precision of a reference measurement system for serum/plasma 25-hydroxyVitamin D analysis. Clin Chim Acta 408:8-13.
Herrmann M, Farrell C-JL, Pusceddu I, et al. (2017) Assessment of Vitamin D status-a changing landscape. Clin Chem Lab Med 55(1):3-26
Ginsberg C, Katz R, de Boer IH, et al. (2018) The 24,25 to 25-hydroxyVitamin D ratio and fracture risk in older adults: The cardiovascular health study. Bone 107:124-130.
Tryfonidou M a, Oosterlaken-Dijksterhuis M a, Mol J a, et al. (2003) 24-Hydroxylase: potential key regulator in hypervitaminosis D3 in growing dogs. Am J Physiol Endocrinol Metab 284:E505-13.
Berg AH, Powe CE, Evans MK, et al. (2015) 24,25-DihydroxyVitamin D3 and Vitamin D Status of Community-Dwelling Black and White Americans. Clin Chem 61(6):877-84.
Bosworth CR, Levin G, Robinson-cohen C, et al. (2012) The serum 24,25-dihydroxyVitamin D concentration, a marker of Vitamin D catabolism, is reduced in chronic kidney disease. Kidney Int 82:693-700.
Schlingmann KP, Kaufmann M, Weber S, et al. (2011) Mutations in CYP24A1 and Idiopathic Infantile Hypercalcemia. N Engl J Med 365:410-421.
Molin A, Baudoin R, Kaufmann M, et al. (2015) CYP24A1 mutations in a cohort of hypercalcemic patients: Evidence for a recessive trait. J Clin Endocrinol Metab 100:E1343-E1352.
Ferraro PM, Minucci A, Primiano A, et al. (2016) A novel CYP24A1 genotype associated to a clinical picture of hypercalcemia, nephrolithiasis and low bone mass. Urolithiasis 25:1-4.
Tai SS-C, Nelson M a. (2015) Candidate Reference Measurement Procedure for the Determination of (24 R ),25-DihydroxyVitamin D3 in Human Serum Using Isotope-Dilution Liquid Chromatography-Tandem Mass Spectrometry. Anal Chem 87:7964-7970.
Wise SA, Tai SSC, Burdette CQ, et al. (2017) Role of the national institute of standards and technology (NIST) in support of the Vitamin D initiative of the national institutes of health, office of dietary supplements. J AOAC Int 100:1260-1276.