Paper published in a journal (Scientific congresses and symposiums)
Comparison of the impedance cardiogram with continuous wave radar using body-contact antennas
Buxi, D.; Dugar, R.; Redouté, Jean-Michel et al.
2017In Conference Proceedings: Annual International Conference of the IEEE Engineering in Medicine and Biology Society, p. 693-696
Peer reviewed
 

Files


Full Text
2017 - Comparison of the impedance cardiogram with continuous wave radar using body-contact antennas.pdf
Publisher postprint (1.55 MB)
Request a copy

All documents in ORBi are protected by a user license.

Send to



Details



Keywords :
Electric Impedance; Electrocardiography; Humans; Male; Radar; Reproducibility of Results; Signal Processing, Computer-Assisted
Abstract :
[en] This paper describes a continuous wave (CW) radar system with body-contact antennas and basic signal processing. The goal is to assess the signals' reproducibility across different subjects as well as a respiration cycle. Radar signals using body-contact antennas with a carrier frequency of 868 MHz are used to acquire the cardiac activity at the sternum. The radar I and Q channel signals are combined to form their magnitude. Signals are collected from six healthy males during paced breathing conditions. The electrocardiogram (ECG) and impedance cardiogram (ICG) signals are acquired simultaneously as reference. The chosen feature in the radar signal is the maximum of its second derivative, which is closest to the ICG B-point. The median and mean absolute errors in pre-ejection period (PEP) in milliseconds between the ICG's B-point and chosen feature in the radar signal range from -6-119.7 ms and 7.8-62.3 ms for all subjects. The results indicate that a reproducible radar signal is obtained from all six subjects. More work is needed on understanding the origin of the radar signals using ultrasound as a comparison. © 2017 IEEE.
Disciplines :
Electrical & electronics engineering
Author, co-author :
Buxi, D.;  Monash University, Melbourne, Australia
Dugar, R.;  Monash University, Melbourne, Australia
Redouté, Jean-Michel  ;  Université de Liège - ULiège > Dép. d'électric., électron. et informat. (Inst.Montefiore) > Systèmes microélectroniques intégrés
Yuce, M. R.;  Monash University, Melbourne, Australia
Language :
English
Title :
Comparison of the impedance cardiogram with continuous wave radar using body-contact antennas
Publication date :
2017
Event name :
39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2017
Event date :
11 July 2017 through 15 July 2017
Audience :
International
Journal title :
Conference Proceedings: Annual International Conference of the IEEE Engineering in Medicine and Biology Society
ISSN :
1557-170X
Publisher :
Institute of Electrical and Electronics Engineers Inc.
Pages :
693-696
Peer reviewed :
Peer reviewed
Commentary :
9781509028092
Available on ORBi :
since 07 June 2019

Statistics


Number of views
47 (3 by ULiège)
Number of downloads
3 (3 by ULiège)

Scopus citations®
 
6
Scopus citations®
without self-citations
2
OpenCitations
 
4

Bibliography


Similar publications



Contact ORBi