[en] We evaluated the performance of the Emit® tox benzodiazepine and barbiturate assays (Dade Behring) and fluorescence polarisation immunoassay (FPIA) (Abbott) for use with serum determinations in preliminary therapeutic drug monitoring or acute drug intoxication detection. Performance, as indicated by CVs, of the Emit® tox benzodiazepine and barbiturate assays and FPIA showed that both immunochemical techniques are precise and have good reproducibility. For within-run studies, results from benzodiazepine determinations showed maximum CV values of 1.91% for the Emit® method and 2.65% for FPIA; results from barbiturate determinations showed maximum CV values of 2.01% for the Emit® method and 1.89% for FPIA. For between-run studies, results from benzodiazepine determinations showed maximum CV values of 1.79% for the Emit® method and 1.12% for FPIA; results from barbiturate determinations showed maximum CV values of 2.09% for the Emit® method and 2.02% for FPIA.
Disciplines :
Pharmacy, pharmacology & toxicology
Author, co-author :
Charlier, Corinne  ;  Université de Liège - ULiège > Département de pharmacie > Chimie toxicologique
Plomteux, Guy ;  Université de Liège - ULiège > Services généraux (Faculté de médecine) > Relations académiques et scientifiques (Médecine)
Language :
English
Title :
Evaluation of EMIT tox benzodiazepine and barbiturate assays on the Vitalab Viva analyser and FPIA on the Abbott ADx analyser
Publication date :
2000
Journal title :
Clinical Chemistry and Laboratory Medicine
ISSN :
1434-6621
eISSN :
1437-4331
Publisher :
Walter de Gruyter, Berlin, Germany
Volume :
38
Issue :
7
Pages :
615-618
Peer reviewed :
Peer Reviewed verified by ORBi
Available on ORBi :
since 20 May 2010

Statistics


Number of views
50 (4 by ULiège)
Number of downloads
0 (0 by ULiège)

Scopus citations®
 
3
Scopus citations®
without self-citations
3
OpenCitations
 
5

Bibliography


Similar publications



Contact ORBi