Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/133184
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Differences in peritoneal dialysis technique survival between patients treated with peritoneal dialysis systems from different companies
Author: Boudville, N.
Ullah, S.
Clayton, P.
Sud, K.
Borlace, M.
Badve, S.V.
Chakera, A.
Johnson, D.W.
Citation: Nephrology Dialysis Transplantation, 2019; 34(6):1035-1044
Publisher: Oxford University Press
Issue Date: 2019
ISSN: 0931-0509
1460-2385
Statement of
Responsibility: 
Neil Boudville, Shahid Ullah, Phil Clayton, Kamal Sud, Monique Borlace, Sunil V Badve ... et al.
Abstract: BACKGROUND:A number of peritoneal dialysis (PD) systems are available but there have been few studies comparing them. The aim of this study was to examine technique failure and patient survival between different PD company systems. METHODS:The study included all patients who commenced PD between 1995 and 2014 in Australia and New Zealand. Groups were compared according to the initial PD company system that they received. The primary outcome was a composite of PD technique failure and death. RESULTS:A total of 16 575 patients commenced PD using systems manufactured by Baxter [n = 13 438 (81%)], Fresenius Medical Care [n = 2848 (17%)] or Gambro [n = 289 (2%)]. Of these, 11 870 (72%) developed technique failure, including 5421 (33%) who died. The median time to technique failure or death for all patients was 625 [interquartile range (IQR) 318-1114] days: 629.5 (IQR 321-1121) days with Baxter, 620.5 (IQR 311-1069) days with Fresenius Medical Care and 538 (IQR 272-1001) days with Gambro systems (P = 0.023). There was a statistically significant increase in technique failure or mortality rates in patients on Gambro {adjusted incidence rate ratio [IRR] 1.46 [95% confidence interval (CI) 1.33-1.62]} and Fresenius [adjusted IRR 1.10 (95% CI 1.01-1.19)] systems compared with Baxter systems. No difference in patient survival was observed between the three PD systems. CONCLUSIONS:PD systems manufactured by different companies may be associated with important differences in PD technique survival. This needs to be confirmed with adequately powered, prospective randomized controlled clinical trials.
Keywords: chronic renal failure
dialysis
epidemiology
peritoneal dialysis
survival analysis
Rights: © The Author(s) 2018. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved. This article is published and distributed under the terms of the Oxford University Press, Standard Journals Publication Model (https://academic.oup.com/journals/pages/open_access/funder_policies/chorus/standard_publication_model)
DOI: 10.1093/ndt/gfy340
Published version: http://dx.doi.org/10.1093/ndt/gfy340
Appears in Collections:Medicine publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.