Smartphone-based Janus micromotors strategy for motion-based detection of glutathione
Identifiers
Permanent link (URI): http://hdl.handle.net/10017/59153DOI: 10.1021/acs.analchem.1c02947
ISSN: 0003-2700
Date
2021-11-22Academic Departments
Universidad de Alcalá. Departamento de Química Analítica, Química Física e Ingeniería Química
Teaching unit
Unidad docente Química Analítica e Ingeniería Quimica
Funders
Ministerio de Ciencia e Innovación
Ministerio de Economía, Industria y Competitividad
Comunidad de Madrid
Bibliographic citation
Analytical Chemistry, 2021, v. 93, n. 46, p. 16385-16392
Project
info:eu-repo/grantAgreement/MICINN//PID2020-118154GB-I00/ES/
info:eu-repo/grantAgreement/MINECO//RYC-2015-17558/ES/
info:eu-repo/grantAgreement/MINECO//CTQ2017-86441-C2-1-R/ES/
info:eu-repo/grantAgreement/CAM//JIN%2F2019-007/ES/
info:eu-repo/grantAgreement/CAM//PEJ-2020-AI%2FIND-17560/ES/
Document type
info:eu-repo/semantics/article
Version
info:eu-repo/semantics/publishedVersion
Rights
© The Authors
Attribution 4.0 International (CC BY 4.0)
Access rights
info:eu-repo/semantics/openAccess
Abstract
Herein, we describe a Janus micromotor smartphone platform for the motion-based detection of glutathione. The system compromises a universal three-dimensional (3D)-printed platform to hold a commercial smartphone, which is equipped with an external magnification optical lens (20-400x) directly attached to the camera, an adjustable sample holder to accommodate a glass slide, and a light-emitting diode (LED) source. The presence of glutathione in peroxide-rich sample media results in the decrease in the speed of 20 mu m graphene-wrapped/PtNPs Janus micromotors due to poisoning of the catalytic layer by a thiol bond formation. The speed can be correlated with the concentration of glutathione, achieving a limit of detection of 0.90 mu M, with percent recoveries and excellent selectivity under the presence of interfering amino acids and proteins. Naked-eye visualization of the speed decrease allows for the design of a test strip for fast glutathione detection (30 s), avoiding previous amplification strategies or sample preparation steps. The concept can be extended to other micromotor approaches relying on fluorescence or colorimetric detection for future multiplexed schemes.