Temperature Gradient Estimation of Floating Zone Furnace by Mean Lamellar Spacing Measurement in DS-processed TiAl AlloysTemperature Gradient Estimation of Floating Zone Furnace by Mean Lamellar Spacing Measurement in DS-processed TiAl Alloys

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 513
  • Download : 0
In this study, the temperature gradient of a floating zone (FZ) apparatus, which is very difficult to directly measure, could be estimated by using the relationships between the lamellar spacing of directionally solidified TiAl alloys and the solidification rate, It was found that the calculated temperature gradient of the FZ apparatus was much higher, and almost ten times higher than that of a Bridgman type directional solidification apparatus.
Publisher
한국열처리공학회
Issue Date
2015-03
Language
Korean
Citation

열처리공학회지, v.28, no.2, pp.82 - 86