(A) highly sensitive bolometer structure with electrostatic-actuated signal bridge정전력으로 구동하는 신호다리를 갖는 높은 감지도의 볼로메타 구조

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 649
  • Download : 0
In this work, a novel bolometer structure has been proposed to achieve high detectivity. For the purpose, it is desirable to lower the bolometer’s thermal conductance. However, the thermal conductance of a traditional metal bolometer structure is usually larger than $1 x 10^{-7} W/K$ in a two-level structure due to the use of metal wires, located on supporting legs, for reading signal. In the proposed bolometer structure, movable bridges were employed to lower the thermal conductance of the bolometer. Therefore, its thermal conductance was unaffected by that of the metal wire by separating the metal wire and the supporting leg into two parts such as a bridge and a post, respectively. The movable bridges were actuated by electrostatic force applied between the bottom electrode and the bridges. Analytical calculations and simulations of the bolometer to optimize design parameters were performed and bolomters were fabricated using the optimized parameters. First, mechanical properties were investigated. In order to lower the pull-in voltage, we used a method that the aluminum film was first sputtered at high temperatures more than room temperature and then the polyimide curing process followed, thereby producing the pull-in voltage of about 8 V. The switching time of the signal bridge was less than 1 ms. The flat membrane was obtained by depositing stress-controlled films and using the thermal annealing method for adjusting the stress of the titanium film. Secondly, thermal and optical properties were investigated. The TCR value of the resistor was -0.275 %/K. Measured thermal conductance of the two legs was $4.13 \times 10^{-8}$ [W/K], which is lower than those of traditional metal bolometers. Thermal response time was measured to be 10 ms enough for a bolometer with a frame rate of 30 Hz. Taking Johnson, 1/f, temperature fluctuation, and background fluctuation noise into consideration, total noise voltage was 15.57 mV. As a result, the responsivity ...
Advisors
Lee, Hee-Chulresearcher이희철researcher
Description
한국과학기술원 : 전기및전자공학전공,
Publisher
한국과학기술원
Issue Date
2006
Identifier
254401/325007  / 020025084
Language
eng
Description

학위논문(박사) - 한국과학기술원 : 전기및전자공학전공, 2006.2, [ ix, 102 p. ]

Keywords

bolometers,uncooled infrared detector; Actuators; microelectromechanical devices; 미소기전소자; 냉각형 적외선 감지 소자; 볼로메타; 엑추에이터

URI
http://hdl.handle.net/10203/35348
Link
http://library.kaist.ac.kr/search/detail/view.do?bibCtrlNo=254401&flag=dissertation
Appears in Collection
EE-Theses_Ph.D.(박사논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0