Título: Testing System for PV Grid-Connected Power Condition Systems with Support for Ancillary Services
Autor: Pires, Vítor Fernão
Cordeiro, Armando
Foito, Daniel
Martins, João F.
Pires, Armando
Chen, Hao
Palavras-chave: ancillary services
photovoltaic system
PV standards
testing system
Engineering (miscellaneous)
Mechanical Engineering
Industrial and Manufacturing Engineering
SDG 7 - Affordable and Clean Energy
Data: 4-Mar-2023
Resumo: Due to the high spread of photovoltaic (PV) systems in the low voltage distribution grids there is a substantial number of requirements for the connection of these systems. Therefore, several tests should be performed before the integration of the PV systems into the grid. Moreover, new requirements have been established that are most likely to be implemented in the near future. To provide these tests and verify if PV systems are in accordance with requirements and recommendations, a testing setup for the PV systems was developed. This testing system consists of a controllable power source prepared to receive energy and to inject it into the grid. In fact, that system imposes a controllable voltage, in amplitude and frequency, to the PV system to simulate the perturbations of the grid. Since the system under test must inject energy in accordance with the standards’ specifications, then the controllable power source that emulates the grid must receive that energy. Moreover, it should also be prepared for PV systems that are able to provide ancillary services, including new ones that support imbalanced networks. A fast and robust control system will be used for this controllable power source. Several experimental tests from the developed prototype are presented.
Descrição: Funding Information: This work was supported by national funds through FCT—Fundação para a Ciência e a Tecnologia with reference UID/CEC/50021/2020 and UID/EEA/00066/2020. Publisher Copyright: © 2023 by the authors.
Peer review: yes
URI: http://hdl.handle.net/10362/155113
DOI: https://doi.org/10.3390/designs7020040
ISSN: 2411-9660
Aparece nas colecções:Home collection (FCT)

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Testing_System_for_PV_Grid_Connected_Power_Condition.pdf4,82 MBAdobe PDFVer/Abrir


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpace
Formato BibTex MendeleyEndnote 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.