Título: Evaluation of administered dose using portal images in craniospinal irradiation of pediatric patients
Autor: Coelho, Carina Marques
Calçada, Raquel
Rodrigues, Sofia
Barragán, Juan Antonio
Sá, Ana Cravo
Macedo, Ana Paula
Monsanto, Fátima
Palavras-chave: Radiotherapy
Craniospinal irradiation
Pediatric tumors
Portal images
Radiation exposure
Data: Mar-2017
Editora: Springer Publishing Company
Citação: Coelho CM, Calçada R, Rodrigues S, Barragán JA, Sá AC, Monsanto F, et al. Evaluation of administered dose using portal images in craniospinal irradiation of pediatric patients. Radiol Phys Technol. 2017 Mar 21. [Epub ahead of print]
Resumo: This study aimed to assess the administered dose based on portal imaging in craniospinal pediatric irradiation by evaluating cases in which portal images did or did not account for the total administered dose. We also intended to calculate the mean increase in total administered dose. Data were collected from General University Hospital Gregorio Marañón; we evaluated the total dose administered, total dose planned, number of portal images per treatment and corresponding monitor units of two different groups: one in which the dose from portal images is deducted from the total administered dose (D), and another in which it was not (N). We used descriptive statistics to analyze the collected data, including the mean and respective standard deviation. We used the Shapiro-Wilk and Spearman rank correlation coefficient tests and estimated the linear regression coefficients. Patients in group D received a mean dose of 29.00 ± 10.28 cGy based on the verification portal images, a quantity that was deducted from the planned dose to match the total administered dose. Patients in group N received a mean dose of 41.50 ± 30.53 cGy, which was not deducted from the planned dose, evidencing a mean increase of 41.50 ± 30.55 cGy over the total administered dose. The acquisition of the set-up verification portal images, without their inclusion in the total administered dose, reflects an average increase in total dose for craniospinal irradiation of pediatric patients. Subtraction of the monitor units used to acquire the verification images is recommended.
Peer review: yes
URI: http://hdl.handle.net/10400.21/7328
DOI: 10.1007/s12194-017-0395-4
Versão do Editor: https://link.springer.com/article/10.1007%2Fs12194-017-0395-4