Buttonhole cannulation of native arteriovenous fistulas (AVFs) appears associated with an increased infectious risk. We previously reported a dramatic increase in the incidence of infectious events after shift to buttonhole in an in-center hemodialysis unit, largely reduced after staff (re)education regarding strict respect of the procedure. We assessed the evolution over the following 12-years period in our center. In this prospective follow-up of a previous, pre (rope-ladder)-post (buttonhole) comparison (2001-2010), all in-center hemodialysis patients with a native AVF were included from July 1st, 2010 to December 31st, 2022. Primary and secondary outcomes were infectious events (unexplained bacteraemia due to skin bacteria and/or local AVF infection) and complicated infectious events (metastatic infection, AVF surgery, death). Overall, the impact of several quality improvement strategies was tested according to the events rate over 6 periods: 1: Rope-ladder in all; 2: switch to buttonhole; 3: buttonhole in all, before workshops; 4: buttonhole in all, after workshops; 5: buttonhole withdrawal in problematic AVFs; 6: additional procedural changes. This extended observation period allowed adding 195,180 AVF-days to our previous report. Overall, 381,661 AVF-days (366 AVFs, 345 patients) were analysed. After an increase of the infectious events rate in 2012, the shift to rope-ladder in problematic AVFs during Period 5 did not have a significant impact. The incidence of infectious events decrease significantly during Period 6 compared to Periods 3, 4 and 5 [IRR 0.24 (95%CI 0.09-0.52) p=0.0001, IRR 0.22 (95%CI 0.09-0.47) p<0.0001, and IRR 0.29 (95%CI 0.11-0.66) p=0.001, respectively] and became eventually for the first time comparable to Period 1 [IRR 0.59 (95%CI 0.21-1.62) p=0.27]. The constant observance of reinforced hygiene protocols by trained staff and central coordination succeeded in significantly mitigating the infectious risk associated with buttonhole.
Bibliographic reference |
Labriola, Laura ; Crott, Ralph ; Desmet, Christine ; Romain, Cécile ; Jadoul, Michel. Infectious Complications Associated to Buttonhole Cannulation of Native Arteriovenous Fistulas: A 22-year follow-up.. In: Nephrology, Dialysis, Transplantation, (2023) |
Permanent URL |
http://hdl.handle.net/2078.1/281067 |