Wide field of view microwave interferometric radiometer imaging
Visualitza/Obre
Cita com:
hdl:2117/134947
Tipus de documentArticle
Data publicació2019-03-02
EditorMultidisciplinary Digital Publishing Institute (MDPI)
Condicions d'accésAccés obert
Llevat que s'hi indiqui el contrari, els
continguts d'aquesta obra estan subjectes a la llicència de Creative Commons
:
Reconeixement-NoComercial-SenseObraDerivada 3.0 Espanya
ProjecteOPTIMIZACION DE LAS PRESTACIONES DE SMOS Y FUTURAS MISIONES (MINECO-TEC2014-58582-R)
PRODUCTOS Y SERVICIOS INNOVADORES CON SENSORES DE MICROONDAS, SMOS Y SENTINELS PARA TIERRA (MINECO-ESP2015-67549-C3-1-R)
PRODUCTOS Y SERVICIOS INNOVADORES CON SENSORES DE MICROONDAS, SMOS Y SENTINELS PARA TIERRA (MINECO-ESP2015-67549-C3-1-R)
Abstract
In microwave interferometric radiometers with a large field of view, as for example the Microwave Imaging Radiometer with Aperture Synthesis (MIRAS) onboard the Soil Moisture and Ocean Salinity (SMOS) satellite, one of the major causes of reconstruction error is the contribution to the visibility of the brightness temperature outside the fundamental period, defined on the basis of reciprocal grids. A mitigation method consisting of estimating this contribution through the application of a brightness temperature model outside the fundamental period is proposed. The main advantage is that it does not require any a posteriori addition of artificial scenes to the reconstructed image. Additionally, a method to avoid the sophisticated matrix regularization and inversion techniques usually applied in microwave interferometry is presented. Image reconstruction algorithms are implemented on a minimum grid size in order to maximize their numerical efficiency. An improved method to apply an apodization window to the reconstructed image for reducing Gibbs oscillations is also proposed. All procedures are generally described considering the single polarization case and successively implemented applying the MIRAS layout in both its single polarization and full polarimetric modes. Results show similar performance of the proposed algorithm with respect to the nominal one applied by SMOS. All algorithms are implemented in the MIRAS Testing Software and have been successfully used for scientific studies by other teams.
CitacióCorbella, I. [et al.]. Wide field of view microwave interferometric radiometer imaging. "Remote sensing", 2 Març 2019, vol. 11, núm. 6, p. 1-17.
ISSN2072-4292
Versió de l'editorhttps://www.mdpi.com/2072-4292/11/6/682