Feasibility of application of sensitivity encoding to the breath-hold T2-weighted turbo spin-echo sequence for evaluation of focal hepatic tumors

Cited 0 time in Web of Science Cited 0 time in Scopus
Authors

Kim, Young Kon; Kim, Chong Soo; Chung, Gyung Ho; Jeon, Su Bin; Lee, Jeong Min

Issue Date
2005-01-27
Publisher
American Roentgen Ray Society
Citation
AJR 2005; 184:497–504
Abstract
OBJECTIVE: The purpose of this study is to assess the feasibility of the application of sensitivity encoding (SENSE) to the T2-weighted breath-hold turbo spin-echo (BHTSE) sequence for evaluating focal hepatic lesions. MATERIALS AND METHODS: Thirty consecutive patients with 43 focal liver lesions underwent BHTSE, BHTSE using SENSE with the conventional parameters, and BHTSE using SENSE with increased matrix and reduced echo-train length (ETL). There were 23 hepatocellular carcinomas in 21 patients, 10 hemangiomas in six, and 10 metastases in three. The images were compared quantitatively by measuring the signal-to-noise ratio (SNR) of the liver and the lesion and the lesion-liver contrast-to-noise ratio (CNR) and qualitatively by evaluating image quality, lesion conspicuity, artifact, and lesion detectability. RESULTS: The SNR of lesions and the lesion-liver CNR were highest on BHTSE using SENSE with increased matrix and reduced ETL, which were significantly higher than conventional BHTSE (p <0.05). In qualitative analysis, the image quality and conspicuity of malignant lesions with BHTSE using SENSE with increased matrix and reduced ETL were better than with BHTSE and BHTSE using SENSE with the conventional parameter (p <0.05). The image artifacts were lower with two BHTSEs using SENSE than with BHTSE (p <0.05). Lesion conspicuity of malignancy on BHTSE using SENSE with the conventional parameter was superior to those on BHTSE (p <0.05). Although there was no significant difference in the lesion detectability among the three images, two malignant lesions were clearly depicted on BHTSE using SENSE with increased matrix and reduced ETL. CONCLUSION: The application of SENSE to BHTSE can provide high-quality liver imaging with decreased acquisition time compared with conventional BHTSE.
ISSN
0361-803X (Print)
1546-3141 (Electronic)
Language
English
URI
http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=15671370

https://hdl.handle.net/10371/10125
Files in This Item:
There are no files associated with this item.
Appears in Collections:

Altmetrics

Item View & Download Count

  • mendeley

Items in S-Space are protected by copyright, with all rights reserved, unless otherwise indicated.

Share