Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/83990

TítuloFuel cells operating as an immunosensor for cancer biomarker screening
Autor(es)Ferreira, Nádia
Carneiro, Liliana
Pinto, Alexandra M. F. R.
Sales, M. G. F.
Palavras-chaveImmunosensor
Direct methanol fuel cell
CA15-3
Cancer biomarker
Point-of-care
Data19-Mar-2023
EditoraElsevier 1
RevistaBiosensors and Bioelectronics: X
CitaçãoFerreira, Nádia; Carneiro, Liliana; Pinto, Alexandra M. F. R.; Sales, M. G. F., Fuel cells operating as an immunosensor for cancer biomarker screening. Biosensors and Bioelectronics: X, No. 100344, 2023
Resumo(s)This work presents the first integration of antibodies into one of the electrodes of a passive direct methanol fuel cell (DMFC) to create an autonomous immunosensor for cancer antigen 153 (CA15-3). The anode of the fuel cell was first made of carbon cloth with carbon black, platinum and ruthenium nanoparticles and then modified with anti-CA15-3, while the cathode was made of carbon cloth with carbon black and platinum nanoparticles. This hybrid DMFC (hDMFC), which works as an immunosensor, was fed with dilute methanol to generate a concentration-dependent current. The hDMFC device was calibrated in different media (buffer and serum), by incubating increasing concentrations of CA15-3 standard solutions, ranging from 47 to 750 U/mL. The linear response ranged from 188 to 563 U/mL, and the limit of detection (LoD) was 39.8 U/mL. The selectivity of the biosensor was also evaluated with competing cancer biomarkers, such as carcinoembryonic antigen (CEA), and cancer antigen 125 (CA-125), as well as with other compounds normally present in blood plasma (ascorbic acid, glucose, uric acid and urea), adjusted to the normal range of concentrations in serum. The results obtained indicate good selectivity of the immunosensor in the fuel cell. In general, the immunosensor showed a good response considering its integration into a passive DMFC. It is a good sensor for point-of-care (PoC) diagnosis because it has a good performance in human serum and, most importantly, it pursues electrical autonomy.
TipoArtigo
URIhttps://hdl.handle.net/1822/83990
DOI10.1016/j.biosx.2023.100344
e-ISSN2590-1370
Versão da editorahttps://www.sciencedirect.com/science/article/pii/S2590137023000419
Arbitragem científicayes
AcessoAcesso aberto
Aparece nas coleções:CEB - Publicações em Revistas/Séries Internacionais / Publications in International Journals/Series

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
document_56208_1.pdf1,35 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID