TítuloSurface AFM microscopy of unworn and worn samples of silicone hydrogel contact lenses
Autor(es)González-Méijome, José Manuel
López-Alemany, António
Almeida, José B.
Parafita, Manuel A.
Palavras-chaveAtomic force microscopy
Contact lens
Polymer deterioration
Surface characterization
degradation
wear
DataJan-2009
EditoraWiley
RevistaJournal of Biomedical Materials Research - Part B: Applied Biomaterials
Citação"Journal of Biomedical Materials Research : applied biomaterials". ISSN 1552-4973. 88B:1 (Jan. 2009) 75-82.
Resumo(s)Abstract: Purpose. To evaluate the qualitative and quantitative topographic changes in the surface of worn contact lenses (CLs) of different materials using atomic force microscopy (AFM). Methods. The topography of five different CL materials was evaluated withAFM over a surface of 25 lm2 according to previously published experimental setup. Average roughness (Ra) and root mean square (Rms) values were obtained for unworn and worn samples. Results. The Ra value increased for balafilcon A (11.62–13.68 nm for unworn and worn samples, respectively), lotrafilcon A (3.67–15.01 nm for unworn and worn samples, respectively), lotrafilcon B (4.08–8.42 nm for unworn and worn samples, respectively), galyfilcon A (2.81–14.6 nm for unworn and worn samples, respectively), and comfilcon A (2.87–4.63 nm for unworn and worn samples, respectively). Differences were statistically significant for all lenses except Rms and Ra for comfilcon A, and Ra parameter for balafilcon A (p > 0.05). The least relative increase was observed for some balafilcon A samples and for some of these samples the roughness decreased after the lenses had been worn. Conclusion. The changes in surface roughness between unworn and worn lenses are different for different silicone-hydrogel materials. Overall all CLs increased the degree of surface roughness after being worn, even for very short periods of time. However, for samples of balafilcon A, roughness increases at a lower extent or even can decrease as compared to unworn samples of the same material due to filling of the macropores.
TipoArtigo
URIhttps://hdl.handle.net/1822/8565
DOI10.1002/jbm.b.31153
ISSN1552-4973
1552-4981
Versão da editorahttp://www3.interscience.wiley.com/
Arbitragem científicayes
AcessoAcesso aberto
Aparece nas coleções:CDF - OCV - Artigos/Papers (with refereeing)

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
5.5.32. GONZALEZ-MÉIJOME_08_JBMR-B (Surface Topography of Si-Hi Worn Lenses).pdfPublished Paper3,4 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID