Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/91112

TítuloNovel yeast-based biosensor for environmental monitoring of tebuconazole
Autor(es)Mendes, Filipa
Miranda, Eduarda
Amaral, Leslie Ann Silva
Carvalho, Carla
Castro, Bruno B.
Sousa, Maria João
Chaves, Susana Alexandra Rodrigues
Palavras-chaveAnalytical tools
Anti-fungal substances
Engineered biosensor
Ergosterol biosynthesis pathway
Pesticide monitoring
Data2024
EditoraSpringer
RevistaApplied Microbiology and Biotechnology
Resumo(s)Abstract: Due to increasing demand for high and stable crop production, human populations are highly dependent on pesticide use for growing and storing food. Environmental monitoring of these agrochemicals is therefore of utmost importance, because of their collateral effects on ecosystem and human health. Even though most current-use analytical methods achieve low detection limits, they require procedures that are too complex and costly for routine monitoring. As such, there has been an increased interest in biosensors as alternative or complementary tools to streamline detection and quantification of environmental contaminants. In this work, we developed a biosensor for environmental monitoring of tebuconazole (TEB), a common agrochemical fungicide. For that purpose, we engineered S. cerevisiae cells with a reporter gene downstream of specific promoters that are expressed after exposure to TEB and characterized the sensitivity and specificity of this model system. After optimization, we found that this easy-to-use biosensor consistently detects TEB at concentrations above 5 μg L−1 and does not respond to realistic environmental concentrations of other tested azoles, suggesting it is specific. We propose the use of this system as a complementary tool in environmental monitoring programs, namely, in high throughput scenarios requiring screening of numerous samples. Key points: • A yeast-based biosensor was developed for environmental monitoring of tebuconazole. •The biosensor offers a rapid and easy method for tebuconazole detection ≥ 5 μg L −1 . •The biosensor is specific to tebuconazole at environmentally relevant concentrations.
TipoArtigo
URIhttps://hdl.handle.net/1822/91112
DOI10.1007/s00253-023-12944-z
ISSN0175-7598
e-ISSN1432-0614
Versão da editorahttps://link.springer.com/article/10.1007/s00253-023-12944-z
Arbitragem científicayes
AcessoAcesso restrito UMinho
Aparece nas coleções:CBMA - Artigos/Papers

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
2024 - mendes et al [Appl Microb Biotech 108].pdf
Acesso restrito!
1,17 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID