English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

Double‐tuned 31P/1H human head array with high performance at both frequencies for spectroscopic imaging at 9.4T

MPS-Authors
/persons/resource/persons133464

Avdievich,  NI
Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons215122

Ruhm,  L
Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons215104

Dorst,  J
Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84187

Scheffler,  K
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84402

Henning,  A
Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

External Resource
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)
There is no public supplementary material available
Citation

Avdievich, N., Ruhm, L., Dorst, J., Scheffler, K., Korzowski, A., & Henning, A. (2020). Double‐tuned 31P/1H human head array with high performance at both frequencies for spectroscopic imaging at 9.4T. Magnetic Resonance in Medicine, 84(2), 1076-1089. doi:10.1002/mrm.28176.


Cite as: https://hdl.handle.net/21.11116/0000-0005-94F6-E
Abstract
PURPOSE:

To develop a robust design of a human head double-tuned 31 P/1 H array, which provides good performance at both 31 P and 1 H frequencies for MR spectroscopic imaging at 9.4T.
METHODS:

Increasing the number of surface loops in a human head array improves the peripheral signal-to-noise ratio (SNR), while the central SNR doesn't substantially change. High peripheral SNR can contaminate MR spectroscopic imaging data at both 1 H and 31 P frequency. To minimize this effect, we limited the number of elements in the 31 P array to 10, i.e., 8 transceiver surface loops circumscribing the head and 2 receive "vertical" loops placed at the superior location. The 1 H-portion of the array also consists of 10 elements, i.e., 8 transceiver surface loops circumscribing the head and 2 transceiver "vertical" loops at the superior location of the head. Both the 31 P array and 1 H array are placed in a single layer at the same distance to the head, which provides high loading and, thus, a good performance for both arrays.
RESULTS:

Transmit efficiency of the 1 H-portion of the double-tuned array was very similar to that of the single-tuned arrays of similar size. Also, addition of the cross-loops substantially improved the brain coverage.
CONCLUSION:

We developed a novel 31 P/1 H double-tuned array for MR spectroscopic imaging of a human brain at 9.4T. Placing both 31 P and 1 H loops in a single layer provides for high transmit efficiency at both frequencies without compromising SNR near the brain center at the 31 P-frequency. Addition of the cross-loops at the superior location improves the brain coverage.